home
***
CD-ROM
|
disk
|
FTP
|
other
***
search
/
Spec Disk 1998 Spring 4.0
/
Spec Disk 1998 Spring 4.0.iso
/
text
/
10165gsp.txt
< prev
next >
Wrap
Text File
|
1998-06-10
|
15KB
|
371 lines
SECTION 10165
PLASTIC LAMINATE TOILET COMPARTMENTS
NOTE ** This section includes plastic laminate toilet
compartments manufactured by Global Steel Products,
Inc., headquartered at the following address:
NOTE ** Global Steel Products, Inc.
NOTE ** 95 Marcus Blvd.
NOTE ** Deer Park NY 11729-4595
NOTE ** Telephone 516-586-3330
NOTE ** FAX 516-586-3455
NOTE **
NOTE ** SECTION 10165 - PLASTIC LAMINATE TOILET
COMPARTMENTS, Copyright 1996, The Architect's
Catalog, Inc.
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Plastic laminate toilet compartments, consisting of:
NOTE ** Delete items below not required for project.
1. Floor-mounted overhead-braced toilet compartments.
2. Floor-mounted toilet compartments.
3. Ceiling-hung toilet compartments.
4. Wall-mounted urinal screens.
B. Compartment installation hardware.
C. Compartment door hardware.
1.2 RELATED SECTIONS
NOTE ** Delete any sections below not relevant to this
project; add others as required.
A. Section 10800 - Toilet, Bath, and Laundry Accessories.
NOTE ** For ceiling hung compartments, structural
suspension and bracing must be specified in another
section. Structural steel, steel channels and
angles, or "Unistrut" are used. Wood structure is
not strong enough. Identify the section where this
structure is specified: Section 05120 - Structural
Steel, or 05500 - Metal Fabrications. Delete
following paragraph if no ceiling hung compartments
are used.
B. Section _____ - Structural support for ceiling hung
compartments.
1.3 SUBMITTALS
A. Submit under provisions of Section 01300.
B. Product Data: Manufacturer's printed literature
indicating typical panel, pilaster, door, hardware and
fastening.
C. Shop Drawings: Submit six sets of the following:
1. Dimensioned plans indicating layout of toilet
compartments.
2. Dimensioned elevations indicating heights of doors,
pilasters, separation partitions, and other
components; indicate locations and sizes of openings
in compartment separation partitions for toilet and
bath accessories to be installed in partitions;
indicate floor and ceiling clearances.
3. Details indicating anchoring components and methods
for project conditions; indicate components required
for installation, but not supplied by toilet
compartment manufacturer.
D. Samples: Two manufacturer's color cards representing
manufacturer's full color palette.
1.4 DELIVERY, STORAGE AND HANDLING
A. Store compartment components until installation in
unopened cartons in vertical position, with adequate
support to ensure flatness and to prevent damage to
prefinished surfaces.
1.5 ENVIRONMENTAL REQUIREMENTS
A. Do not deliver materials or begin construction activities
of this section until building is enclosed, with complete
protection from outside weather, and building temperature
maintained at a minimum of 60 degrees Fahrenheit.
1.6 SEQUENCING
A. Obtain accessory manufacturer's installation instructions
and installation templates for toilet and bath
accessories to be installed in compartment separation
partitions; supply instructions and templates to
installer before beginning construction activities of
this Section.
PART 2 PRODUCTS
2.1 MANUFACTURERS
A. Acceptable Manufacturer: Global Steel Products, Inc.; 95
Marcus Blvd., Deer Park NY 11729-4595; telephone 516-586-
3330, FAX 516-586-3455.
NOTE ** Delete one of the two paragraphs below; coordinate
with Division 1 requirements.
B. Substitutions: Not permitted.
C. Requests for substitutions will be considered in
accordance with provisions of Section 01600.
2.2 PLASTIC LAMINATE TOILET COMPARTMENTS
NOTE ** Delete all but one of following three paragraphs;
Embassy is floor-mounted overhead-braced, Regal is
floor-mounted, Imperial is ceiling-hung.
A. Acceptable Product: Embassy Plastic Laminate Toilet
Compartments.
B. Acceptable Product: Regal Plastic Laminate Toilet
Compartments.
C. Acceptable Product: Imperial Plastic Laminate Toilet
Compartments.
D. Panels:
1. Nominal thickness: 1 inch.
2. Core: Multiple layers high density particleboard
conforming to ANSI 208.1, set with water-resistant
resin binder.
3. Edge Banding: Plastic laminate matching face sheets,
applied to partition edges before applying face
sheets.
4. Face sheets: Plastic laminate conforming to NEMA
LD3, Type GP50, nominal thickness 0.050 inch, applied
to overlap edges of edge banding laminate.
E. Pilasters:
1. Nominal thickness: 1-1/4 inches.
2. Core: Multiple layers high density particleboard
conforming to ANSI 208.1, set with water-resistant
resin binder.
3. Edge Banding: Plastic laminate matching face sheets,
applied to partition edges before applying face
sheets.
4. Face sheets: Plastic laminate conforming to NEMA
LD3, Type GP50, nominal thickness 0.050 inch, applied
to overlap edges of edge banding laminate.
NOTE ** Delete one of two paragraphs below; retain first
paragraph if overhead-braced or floor-mounted
compartments selected; retain second paragraph if
ceiling-mounted compartments selected.
5. Pilaster installation hardware preparation: Two
holes, diameter to accept 3/8 inch threaded rod,
drilled into core at pilaster base end, parallel to
pilaster vertical axis, intersecting centerlines of
two holes, diameter to accept Plug-Loc(tm)
installation hardware, drilled through pilaster
perpendicular to pilaster face and 1 inch from
pilaster base end.
6. Pilaster installation hardware preparation: Two
holes, diameter to accept 3/8 inch threaded rod,
drilled into core at pilaster top end, parallel to
pilaster vertical axis, intersecting centerlines of
two holes, diameter to accept Plug-Loc(tm)
installation hardware, drilled through pilaster
perpendicular to pilaster face and 1 inch from
pilaster top end.
F. Doors:
1. Nominal thickness: 1 inch.
2. Core: Multiple layers high density particleboard
conforming to ANSI 208.1, set with water-resistant
resin binder.
3. Edge Banding: Plastic laminate matching face sheets,
applied to partition edges before applying face
sheets.
4. Face sheets: Plastic laminate conforming to NEMA
LD3, Type GP50, nominal thickness 0.050 inch, applied
to overlap edges of edge banding laminate.
NOTE ** 18 standard colors are available.
G. Color and Finish: Selected from manufacturer's full
color palette.
2.3 ACCESSORIES
A. Pilaster Shoes: Four-piece Type 304 stainless steel
assembly, No. 4 satin finish, hemmed top and bottom
edges.
NOTE ** Delete one of the two paragraphs below. The first
paragraph is for overhead-braced or floor-mounted
compartments, the second paragraph is for ceiling-
hung compartments.
NOTE **
NOTE ** Floor-mounting requires a concrete floor for
adequate anchorage.
NOTE ** Ceiling-mounting requires steel structure for
adequate support.
B. Pilaster Anchors: Manufacturer's standard floor
anchoring system with leveling adjustment, concealed by
pilaster shoe after installation.
C. Pilaster Anchors: Manufacturer's standard ceiling
anchoring system with leveling adjustment, concealed by
pilaster shoe after installation.
NOTE ** Delete paragraph below if urinal screens not
required.
D. Urinal Screen Brackets: Full height 38-inch-long two ear
anodized aluminum with satin finish, prepared for
fastening hardware.
NOTE ** Delete paragraph below if overhead-braced
compartments are not required.
E. Head Rail: Manufacturer's standard anodized aluminum
rail with anti-grip device.
NOTE ** Delete one of the following two sets of paragraphs
on brackets and hardware.
F. Brackets: Heavy duty, die-cast non-ferrous chrome-
plated, with chrome-plated throughbolts and fasteners
with tamper-resistant heads.
G. Door Hardware: Heavy duty, die-cast non-ferrous chrome-
plated.
NOTE ** Stainless steel brackets and hardware are an extra
cost option.
H. Brackets: Die-cast No.304 stainless steel, No.4 satin
finish, with throughbolts and fasteners of same material
and finish with tamper-resistant heads.
I. Door Hardware: Die-cast No.304 stainless steel, with
No.4 satin finish.
NOTE ** The following sub-paragraphs apply to both types of
hardware.
1. Top and Bottom Hinges: Recessed into door with
saddle on adjacent pilaster, providing bi-directional
operation about axis within the plane of the door;
adjustable cams supporting door, returning to resting
position by gravity.
2. Latch: Door-mounted slide latch.
3. Stop and Keeper: Permitting emergency access by
lifting the door until latch is clear of keeper.
4. Coat Hook: Black rubber tip for door stop.
NOTE ** Delete one of the two paragraphs below. The first
paragraph is for non-ferrous hardware; the second
paragraph is for stainless steel hardware.
5. Fastening Hardware: Chrome-plated through-bolts and
attachment fasteners with tamper-resistant heads.
6. Fastening Hardware: Stainless steel with No.4 satin
finish, through-bolts and attachment fasteners with
tamper-resistant heads.
J. Toilet and Bath Accessories for Installation in
Compartment Separation Partitions: Specified Section
10800.
PART 3 EXECUTION
3.1 EXAMINATION
A. Verification of Conditions:
1. Measure areas to receive compartments; verify area
dimensions are in accordance with shop drawings.
2. Verify built-in framing, anchorage, bracing, and
plumbing fixtures are in correct location.
B. Installer's Examination:
1. Have installer of this section examine conditions
under which construction activities of this section
are to be performed, then submit written notification
if such conditions are unacceptable.
2. Transmit two copies of installer's report to
Architect within 24 hr of receipt.
3. Beginning construction activities of this section
before unacceptable conditions have been corrected is
prohibited.
4. Beginning construction activities of this section
indicates installer's acceptance of conditions.
3.2 PREPARATION
A. Surface Preparation:
1. Prepare openings in compartment separation partitions
for toilet and bath accessories to be installed in
partitions; marring of partition finish is
prohibited.
2. Locate openings in accordance with shop drawings and
accessory manufacturer's installation instructions
and templates.
3.3 INSTALLATION
A. Install compartments to specified tolerances in
accordance with shop drawings and manufacturer's printed
installation instructions.
B. Attach components to adjacent materials and to other
components using purpose-designed fastening devices.
NOTE ** Delete one of two paragraphs below.
C. Adjust pilaster anchors for floor variations; conceal
anchors with pilaster shoes.
D. Support pilasters from above ceiling framing using two
adjustable hanging studs for vertical adjustment to
level; conceal ceiling fastenings with pilaster shoes.
NOTE ** The remaining provisions apply to all types of
compartments in this section.
E. Equip each compartment door with top and bottom hinges,
and door latch.
F. Install door strike keeper on pilasters in alignment with
door latch.
G. Equip each compartment door with one coat hook and
bumper.
H. Installation Tolerances:
1. Max. variation from plumb or level: 1/8 inch.
2. Max. displacement from indicated position: 1/8 inch.
3. Clearance between wall surface and panels or
pilasters: 1-1/2 maximum.
3.4 ADJUSTING
A. Adjust door hardware for uniform clearance between doors
and pilasters.
B. Adjust door hinges to attain free movement, to locate
in-swinging doors in partial open position when
unlatched; and to return out-swinging doors to closed
position.
C. Adjust door hardware to align door strike keeper on each
pilaster with door latch.
3.5 PROTECTION OF INSTALLED PRODUCTS
A. Prevent damage to product finishes by subsequent
construction activities.
B. Replace components having damaged finish.
C. Remove factory protective coverings and clean finish
surfaces in accordance with manufacturer's instructions
before final inspection.
3.6 SCHEDULE
NOTE ** If more than one type of partition is required, or
more than one color or finish, a schedule may help
to the types and where they are to be used.
A. Men's Toilet Room No. ___: Floor-mounted overhead-braced
plastic laminate toilet compartments and wall-mounted
urinal screens; _______ color, matte finish.
B. Women's Toilet Room No. ___: Ceiling-hung plastic
laminate toilet compartments; compartment separation
partitions _______ color, matte finish; pilasters _______
color, matte finish; doors to match compartment
separation partitions.
END OF SECTION